Controller Pretrips Report For ____________ Тра 26, 2014 to Тра 27, 2014 System Configuration at the Time of Interrogation: Interrogated On Тра 27, 2014 Extracted By DataLine Rev 2.1.0 Controller Software: 5148 Controller Serial #: 04065030 Bill of Lading #: Origin: Origin Date: Destination: Discharge Date: Comment: Probe Calibration Readings: USDA1 0,0 USDA2 0,0 USDA3 -0,3 Cargo 0,0 Temperature Units: Centigrade _______________________________________________________ Тра 26, 2014 Setpoint: -20,00, O2: OFF, CO2: OFF, Container: _________________, Serial : _________ Time Event Data 20:51 AUTO1 Pre-Trip Initiated By Keypad 20:54 P1-0 Heaters On Test: Passed- A: 4,73, B: 2,55, C: 4,73 P1-1 Heaters Off Test: Passed- A: 4,71, B: 2,57, C: 4,71 P1-2 Remote Heater Test: Not Run- A: 0,00, B: 0,00, Voltage: 0,0 20:55 P2-0 Condenser On Test: Passed- A: 1,10, B: 0,02, C: 1,10, WPS: On P2-1 Condenser Off Test: Passed- A: 1,11, B: 0,89, C: 1,11 20:57 P3-0 Low Evap On Test: Passed- A: 1,00, B: 1,82, C: 1,00 P3-1 Low Evap Off Test: Passed- A: 1,03, B: 1,84, C: 1,03 20:58 P4-0 High Evap On Test: Passed- A: 1,75, B: 3,22, C: 1,75, Ratio: 1,83 P4-1 High Evap Off Test: Passed- A: 1,75, B: 3,26, C: 1,75 P4-2 Remote Evap Fans On Test: Not Run 21:02 P5 Probe Test: P5-0: Passed, P5-1: Passed, P5-2: Passed STS: -1,84, RTS: -1,87, SRS: -1,83, RRS: -1,89 P5-3 Evap Fan Dir Test: Not Run P5 Remote Probe Test: P5-4: Not Run, P5-5: Not Run, P5-6: Not Run P5-7: Not Run P5-8: Not Run P5-9: Not Run P5 Humidity Sensor Test: P5-10: Passed, P5-11: Passed, P5-12: Passed 21:10 P6-0 Compressor Test: Pass- A: 12,79, B: 13,63, C: 12,79 P6-1 Low Speed Compressor Test: Not Run P6-2 Suction Modulation Valve (Open) Test: Pass- A: 4,42, B: 4,44, Diff: 55,89 Current Limit Status: Did not activate Pressure Limit Status: Did not activate HPS Cycle Status: Did not activate CPC Sensor Validity: Did not validate Current limit when full open: Did not validate P6-3 Quench Valve Test: Not Run P6-4 Suction Modulation Valve (Closed) Test: Pass- A: 4,12, B: 4,30 Pressure Difference: 47,99 Current Limit Status: Did not activate Pressure Limit Status: Did not activate HPS Cycle Status: Did not activate CPC Sensor Validity: Did not validate P6-5 Bypass Valve Test: Pass- STS: -9,68, RTS: -4,07, Status: Did not activate P6-6 Unloader Test: Not Run 21:10 Pre-Trip Test Termination P1-0: Passed P1-1: Passed P1-2: Not Run P2-0: Passed P2-1: Passed P3-0: Passed P3-1: Passed P4-0: Passed P4-1: Passed P4-2: Not Run P5-0: Passed P5-1: Passed P5-2: Passed P5-3: Not Run P5-4: Not Run P5-5: Not Run P5-6: Not Run P5-7: Not Run P5-8: Not Run P5-9: Not Run P5-10: Passed P5-11: Passed P5-12: Passed P6-0: Passed P6-1: Not Run P6-2: Passed P6-3: Not Run P6-4: Passed P6-5: Passed P6-6: Not Run P6-7: Not Run P6-8: Not Run P6-9: Not Run P6-10: Not Run P6-11: Not Run P7-0: Not Run P7-1: Not Run P8-0: Not Run P8-1: Not Run P8-2: Not Run P9-0: Not Run P10-0: Not Run P10-1: Not Run P10-2: Not Run _______________________________________________________